RV Air Conditioners and Furnaces

Rooftop AC brands, power draw, thermostat error codes, furnace lockouts and where to get parts.

Most RVs cool with a 13,500 or 15,000 BTU rooftop air conditioner and heat with a propane furnace, sometimes helped by a heat pump. This guide pulls the specs, codes and fixes from manufacturer manuals so you can figure out what you have and what's wrong with it.

QUICK ANSWER

The main rooftop AC brands are Dometic, Coleman-Mach (Airxcel), Furrion (Lippert) and GE. Most fit the standard 14 x 14 in roof opening. A 15,000 BTU unit runs about 13–14 A when cooling and up to 18–20 A in extreme heat, and its compressor can briefly pull 52–73 A when it starts. That's why one AC is about the limit on 30 A service or a small generator unless you add a soft start.

THE BRANDS

Who makes RV air conditioners

Dometic

  • Current US rooftop line: FreshJet 5 (13.5K, 15K and High Efficiency), R32 refrigerant, 10.5 in tall

  • Dometic says the FreshJet 15K is backward compatible with Penguin II models

  • Penguin II, Brisk II and Blizzard NXT no longer appear in Dometic's US listing, but parts are still sold

  • Dometic AC guide

Coleman-Mach (Airxcel)

  • Mach 15, Mach 3 Plus, Mach 10, Mach 8 Plus, Quiet (NDQ) and heat pump models

  • Part-number prefix shows the profile: 38/48 medium, 35/45 low, 37/47 ultra-low

  • New variable-speed units: Everest VS-18, plus VS-14 heat pump models announced Aug 2026

  • Coleman-Mach guide

Furrion (Lippert)

  • Chill HE 13.5K and 15K (R32)

  • Chill Cube 18K variable speed, with or without heat pump, ducted or non-ducted

  • Chill Cube 15K low-profile variable speed with heat pump

  • Thermostat, air distribution box and controller are sold separately

GE Appliances

  • RV rooftop ACs in the ARC, ARH, PLC and PLH families

  • Some older models, such as the ARH15AACB, are no longer made

  • A 2024 recall covered the soft start in many GE RV ACs (see Recalls below)

Also worth knowing: the Truma Aventa eco (13,500 BTU) is sold as a replacement for non-ducted rooftops, and Advent units turn up in some trailers. For vans, Dometic makes a 12V rooftop unit, the CoolAir RTX 2000.

POWER

How much power an RV air conditioner draws

Unit

Running amps (cooling)

Notes

Dometic FreshJet 5 15K (FJX5557M)

12.66–19.73 A

Built-in hard start

Coleman-Mach Mach 15

13.9 A

18 A in "desert" conditions; 16 A with heat strip

Coleman-Mach Mach 10

11.6–14.4 A

14.3–17.5 A in "desert" conditions

Truma Aventa eco (13.5K)

9.4–10.5 A

59 A for 150 ms at start-up

Any rooftop compressor at start

52–73 A for a moment

Dometic's locked-rotor rating for its 13.5K/15K units

30 amp vs 50 amp

  • 30 A service is about 3,600 W, which usually runs one rooftop AC plus light loads

  • 50 A service is two 120 V legs, about 12,000 W, enough for two or more ACs

  • Dometic calls for a 20 A time-delay breaker and 12 AWG wire per AC

Generators and soft starts

  • Dometic recommends at least a 3.5 kW generator for one AC and 5 kW for two, and notes generators lose power at altitude

  • Soft starts such as Micro-Air EasyStart, or Coleman-Mach's kit 1497-3601, cut starting current by up to 75%

  • That can let a 2,000 W generator, or 30 A service, start an AC it otherwise couldn't

REPLACING A UNIT

Will a new AC fit your roof?

The 14 x 14 opening

  • Most rooftop ACs fit the standard 14 x 14 in roof opening; Dometic specifies 14.3 x 14.3 in, plus or minus 0.1 in

  • Dometic requires 1.5 to 6 in from roof to ceiling

  • Low-profile units sit about 8–11 in tall, versus about 14 in for older designs

Ducted or non-ducted

  • Non-ducted units blow straight down through a ceiling assembly (air distribution box)

  • Ducted units feed ceiling ducts and need a ducted ceiling kit and return-air grille

  • Coleman-Mach part numbers ending in DQ are ducted; NDQ are non-ducted

  • Match your thermostat type too: Coleman-Mach 9 Series controls don't work with 8 Series parts

TROUBLESHOOTING

RV air conditioner error codes

Thermostat

Code

What it means

Dometic CCC2

E1

Lost communication with the AC control board(s)

Dometic CCC2

E2 / E3

Indoor temperature sensor open / shorted; fan still works

Dometic CCC2

E4

Outdoor sensor open (select models); heat pump locked out

Dometic CCC2

E5

Freeze sensor open; AC locked out, heat still works

Dometic CCC2

E7

No 120V AC power reaching the control boards

Dometic CCC2

E8 / E9

DIP switch setup conflict in a zone

Dometic single-zone LCD

E1–E5

Same meanings as the CCC2 codes above

Furrion Chill

E1 / E2

Indoor sensor / evaporator sensor fault

Furrion Chill

E3

Thermostat lost communication with the control box

Furrion Chill

lo

12V supply to the thermostat is too low

Coleman-Mach 9330

Er

Temperature out of range or remote sensor failed

Coleman-Mach 9330

GAS flashing

Backup furnace is helping the heat pump (not a fault)

From Dometic, Furrion and Airxcel thermostat manuals. Coleman-Mach doesn't publish an E-code list for its 9430 and Bluetooth thermostats, so be wary of code lists online that claim to. On Coleman-Mach zone systems, a dark green LED on the control board means low 12V control power, and the system won't run below 9.75 VDC.

BEFORE YOU CALL A TECH

Four checks for an AC that won't cool

1

Clean the filter

Dometic says to clean the return-air filter at least every two weeks of use, and never to run the AC without it.

2

Thaw a frozen coil

Ice forms with a dirty filter, closed vents or cool nights. Switch to fan only until it clears and keep at least two vents open.

3

Check power

Check the 120V breaker, shore-power or generator output and campground voltage. Low voltage is hard on compressors.

4

Wait 2 minutes

Compressors have a built-in restart delay of about 2 minutes. Cycling the power quickly can look like a failure.

FURNACES

RV furnaces: Suburban and Dometic (Atwood)

RV furnaces burn propane but run their blower and controls on 12V. The blower starts first, a sail switch proves there's enough airflow, and only then does the board try to light the burner. After 3 failed tries, the furnace locks out.

Suburban (Airxcel)

  • The sail switch closes at about 75% blower speed; weak 12V or lint on the blower keeps it open

  • Needs 10.5–13.5 VDC and 11–14 in WC propane pressure

  • Reset a lockout by turning the thermostat off, then on

  • Don't add air boosters to the ducts; Suburban says they make the sail switch act up

  • Check the outside vent for soot and insect nests; have it inspected yearly

  • Suburban's manuals don't list LED blink codes

Dometic DF series (formerly Atwood)

Board LED codes from Dometic's DF furnace manual:

LED

What it means

Steady on

Control board failure (hard lockout)

1 flash

Limit switch or airflow problem

2 flashes

Flame sense fault (hard lockout)

3 flashes

Failed to ignite (retries after 1 hour)

4 flashes

Voltage too high (16–17V)

5 flashes

Voltage too low (8–9V)

Reset: thermostat off for 10 seconds, then on. Repeat up to 3 times if there may be air in the propane line.

Suburban: (423) 775-2131 · Dometic: (800) 544-4881. Both makers recommend annual service by a qualified RV technician. Furnace parts by model: RV Furnace Guys.

HEAT PUMPS AND SAFETY

Heat pumps, heat strips and CO

Heat pumps

  • A heat pump AC heats efficiently in mild weather but loses output as it gets colder

  • Dometic's CCC2 switches to the furnace below 30°F outside and back above 35°F

  • A heat strip is supplemental heat only and doesn't replace a furnace

Carbon monoxide

  • Never cover or screen the furnace vent, and keep snow off it

  • Shut the furnace down if you see soot around the vent

  • Test the LP/CO alarm weekly in use; many must be replaced within 5 years

  • If the CO alarm sounds, get everyone to fresh air and call 911

RECALLS

RV air conditioner and furnace recalls

GE RV air conditioners: soft start (NHTSA 24E071)

  • Covers the ICM870 soft start in GE ARC, ARH, PLC and PLH rooftop ACs built June 1, 2022 – May 29, 2024, because of a risk of smoke or a thermal event

  • The fix is a replacement soft start in a metal enclosure. GE: 1-800-772-7262. Forest River filed a matching vehicle recall (24V771).

We found no 2020–2026 NHTSA equipment recalls for Dometic, Coleman-Mach, Furrion or Suburban rooftop ACs or furnaces (checked October 2026). Check your RV's VIN at nhtsa.gov/recalls.

WHERE TO BUY

Where to buy RV AC and furnace parts

Store

Type

AC and heating parts

Good for

Category specialist

Coleman-Mach (authorized retailer), Dometic, Furrion, Advent and GE units and parts

Matching parts to your model; free shipping on new rooftop ACs

Category specialist

Suburban and Dometic (Atwood) furnaces and parts by model: control boards, sail switches, gas valves, blowers

Furnace parts matched to your model

RV and trailer parts retailer

Dometic, Coleman-Mach and Furrion parts

Free staff answers to product questions

Manufacturer (Furrion)

Furrion Chill units and parts

Buying Furrion direct

National RV dealer

ACs, furnaces and parts

Having a unit installed in person

Local RV dealer or mobile tech

Service

Warranty work, furnace service

Annual furnace service, warranty claims

Store details checked October 2026. Have your model and serial number ready before ordering. Free help: Dometic support · Coleman-Mach library · Suburban documents · Furrion support · iRV2 forums

QUESTIONS

RV heating and cooling FAQ

What size AC opening do RVs use?

Most RV rooftop air conditioners fit a standard 14 x 14 inch roof opening. Dometic specifies 14.3 x 14.3 inches, plus or minus 0.1 inch, and 1.5 to 6 inches from roof to ceiling.

How many amps does an RV air conditioner use?

A 13,500 or 15,000 BTU rooftop unit typically draws about 12–14 amps while cooling and up to 18–20 amps in extreme heat. The compressor can briefly pull 52–73 amps at start-up.

Can I run two ACs on 30 amp service?

Usually not at the same time. 30 amp service is about 3,600 watts, which is roughly one rooftop AC plus light loads. A soft start can make it possible on some setups, but 50 amp service is the normal way to run two.

What generator do I need for an RV air conditioner?

Dometic recommends at least a 3.5 kW generator for one rooftop AC and 5 kW for two. With a soft start, many single ACs will start on a 2,000-watt inverter generator.

What does E1 mean on a Dometic thermostat?

On Dometic CCC2 and single-zone LCD thermostats, E1 means the thermostat lost communication with the AC control board, and the system shuts down. Check 12V power and the thermostat cable.

Why won't my RV furnace light?

Common causes are low 12V battery voltage, propane supply problems or air in the line, a blocked return or lint keeping the sail switch open, and a dirty or misgapped igniter. After 3 failed tries the furnace locks out; turn the thermostat off and on to reset.

NEED AN AC PART OR A NEW UNIT?

Start with your model number

RV AC Guys carries Coleman-Mach, Dometic, Furrion, Advent and GE air conditioners and parts, and will help you match the right one.

Dometic_-_logo-2.png
suburban-logo.png
ColemanMach_AnAirxcelBrand.png
thetford-vector-logo-2.png
splendide-logo.png
5d75aa290667d2f9f1b4bda769381148.jpg
Norcold_logo__29741.png
CamcoLogo.png.avif
*content curated from dealerships, service centers, and industry professionals.
Furrion_Master_Logo_RichBlack.jpg
Girard_Logo_Locked_Up_2c_black_and_red-orange_on_transparent.webp

© 2026 by RV Guidance

bottom of page